232Th, 230Th and 231Pa from 5L seawater for mass spectrometry
Sample Type | Water |
---|---|
Elements | Pa Th |
Radioisotopes | 230Th, 231Pa |
Detection by | Magnetic Sector ICP-MS | Description | This method is used for the measurement of dissolved 232Th, 230Th, and 231Pa from water samples. Samples are collected in acid-cleaned 5-liter cubitainers, and acidified at sea to pH=2 using Optima grade 6M hydrochloric acid. The following method is for radionuclide analysis once the samples have been returned to Lamont-Doherty. This procedure is for analyzing one batch – which includes 15 samples, 2 procedural blanks, 2 seawater standards, and one column blank. |
Source | R. Anderson |
Year | 2017 |
View Recipe (pdf) |